				| Services Available | |
|---|---|
| Repair | No | 
| Calibration | No | 
| Free Support | No | 
The SDM-INT8 outputs timing data to a Campbell Scientific data logger. The data logger can process the timing data to calculate RPM, duty cycle, velocity, crank angle, etc.
Read More 
				The SDM-INT8 has eight channels that are individually programmed to record the timing of input voltage transitions (events). It uses this information to output:


The data logger enables individual modules through an addressing scheme; up to 15 SDM-INT8s can be connected to one data logger. After a module is enabled, it operates independently of the data logger until additional commands are received or results are transmitted.
| Operating Voltage | 9.6 to 16 Vdc | 
| Current Drain | 
 | 
| Maximum Timing Measurement | 16.7 s | 
| Resolution | ±1 µs | 
| Operating Temperature | -25° to +50°C | 
| Dimensions | 0.3 x 12.7 x 2.5 cm (8 x 5 x 1 in.) | 
| Weight | 0.82 kg (1.8 lb) | 
| High-Level Voltage Input Pulses | |
| Minimum Pulse Width | 2 µs | 
| Maximum Frequency (32-bit values) | 
 | 
| Maximum Frequency (16-bit values) | 
 | 
| Low-Level AC Voltage Input | |
| AC Voltage | 
 | 
| Input Hysteresis | 11 mV | 
| Minimum Frequency | 1 Hz | 
| Maximum Frequency | 
 | 
Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.
| Product | Compatible | Note | 
|---|---|---|
| 21X (retired) | ||
| CR10 (retired) | ||
| CR1000 (retired) | ||
| CR10X (retired) | ||
| CR200X (retired) | ||
| CR206X (retired) | ||
| CR211X (retired) | ||
| CR216X (retired) | ||
| CR23X (retired) | ||
| CR295X (retired) | ||
| CR3000 (retired) | SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3. | |
| CR500 (retired) | ||
| CR5000 (retired) | SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3. | |
| CR510 (retired) | ||
| CR6 | ||
| CR800 (retired) | ||
| CR850 (retired) | ||
| CR9000 (retired) | SDMs connect to ports provided on the CR9080 PAM module. | |
| CR9000X (retired) | SDMs connect to ports provided on the CR9032 CPU module. | 
| Product | Compatible | Note | 
|---|---|---|
| ENC10/12 | ||
| ENC10/12R | ||
| ENC12/14 | ||
| ENC14/16 | ||
| ENC16/18 | ||
| ENC24/30 | ||
| ENC24/30S | 
| Product | Compatible | Note | 
|---|---|---|
| Granite 10 | ||
| Granite 6 (retired) | ||
| Granite 9 | 
The SDMINT8 instruction controls the SDM-INT8 operation in CRBasic. Instruction 101 controls the SDM-INT8 operation in Edlog.
The SDM-INT8 draws 20 mA. In most applications, the data logger’s sealed rechargeable power supply can be used. The data logger’s alkaline power supply has sufficient capacity to operate the SDM-INT8 during short-term installations only.
The SDM-INT8 should be housed in an environmental enclosure. A bracket is shipped with the SDM-INT8 for mounting it to an enclosure backplate.